Pool, spa and hot tub wiring in corrosive areas uses the permitted methods (RMC, IMC, PVC/RTRC, LFNMC, limited LFMC and MC, short cords); elsewhere Chapter 38 applies (NEC 680.14, 680.21, 680.23).
Dishwashers, ranges, wall ovens, cooktops, dryers, microwaves, sump pumps, pressure washers and water coolers up to 150 V to ground and 60 A get GFCI protection (NEC 210.8(D)).
Local review: GFCI coverage here follows the 2023 NEC; confirm San Antonio's adopted NEC edition before relying on the expanded list.
Counters and work surfaces 12 in or wider in kitchens, pantries, breakfast and dining areas get receptacles; each 12 in of multioutlet assembly counts as one (NEC 210.52(C)).
A Class 2 circuit is powered by a listed Class 2 transformer, power supply, marked equipment, IT/AV limited-power circuit or listed Class 2 battery (NEC 725.60(A)).
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.