Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 677 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • E4001.2

    Snap-Switch Terminations

    • 15 and 20 A switch terminals not marked CO/ALR take copper or copper-clad aluminum only; push-in terminals are for 15 A circuits and 14 AWG solid copper unless listed otherwise.

    International Residential Code, 2024 · Chapter 40, Devices and LuminairesRead the full text (opens UpCodes in a new tab)

  • E3609.5

    Sizing Supply-Side Bonding Jumper and Main Bonding Jumper

    • Supply-side and main bonding jumpers are at least the GEC size from Table E3603.4, based on the conductors in each raceway for parallel sets (NEC 250.102(C)).

    International Residential Code, 2024 · Chapter 36, ServicesRead the full text (opens UpCodes in a new tab)

  • E4203.4.7

    Low-Voltage Gas-Fired Luminaires, Decorative Fireplaces, Fire Pits and Similar Equipment

    • Listed low-voltage gas fire features and lights may be within 5 ft of the pool, with metal parts and gas piping bonded (NEC 680.22(B)(7)).

    Works withE4204.2E4206.9.1E3609.7

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4005.2

    Fittings

    • Only matching track fittings, securely fastened, polarized and grounded, with no general-purpose receptacles (NEC 410.150(A), (D)).

    International Residential Code, 2024 · Chapter 40, Devices and LuminairesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application