Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 677 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • E3908.9.2

    Liquid-Tight Flexible Metal Conduit

    • LFMC is an EGC with listed fittings: 3/8-1/2 at 20 A max, 3/4-1 1/4 at 60 A max, 6 ft total flex; stainless-core or flexing installs need a wire EGC (NEC 250.118(6)).

    International Residential Code, 2024 · Chapter 39, Power and Lighting DistributionRead the full text (opens UpCodes in a new tab)

  • E3907.2

    Damp and Wet Locations

    • Surface cabinets in damp or wet locations keep water out with a 1/4 in airspace behind; wet ones are weatherproof (NEC 312.2).

    International Residential Code, 2024 · Chapter 39, Power and Lighting DistributionRead the full text (opens UpCodes in a new tab)

  • E4206.14.1

    Unit Heaters

    • Unit heaters are rigidly mounted, enclosed or guarded, and not over the pool or within 5 ft of it (NEC 680.27(C)(1)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E3905.6.3

    Weight-Supporting Ceiling Receptacles (WSCR) and Weight-Supporting Attachment Fittings (WSAF)

    • Lighting and fan boxes may hold listed weight-supporting ceiling receptacles with matching attachment fittings, counted in box fill (NEC 314.27(E)).

    International Residential Code, 2024 · Chapter 39, Power and Lighting DistributionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application