15 sections matching “E4206.1” for San Antonio, TX, the 2024 IRC

  • E4206.1

    Transformers and Power Supplies

    • Underwater luminaire transformers and power supplies are listed for pools, isolated-winding with a grounded barrier or double-insulated (NEC 680.23(A)(2)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.11

    Electrically Operated Pool Covers

    • Pool cover motors and controls are 5 ft from the pool unless behind a barrier, totally enclosed if below grade, GFCI-protected, with the control in full view of the pool (NEC 680.27(B)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.12

    Electric Pool Water Heaters

    • Electric pool heaters split elements into loads of 48 A or less protected at 60 A max, with circuits sized at 125% of nameplate (NEC 680.10).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.13

    Electrically Powered Swimming Pool Heat Pumps and Chillers

    • Pool heat pumps and chillers are listed, with conductors and breakers per the nameplate (NEC 680.10(B)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.10.1

    Speakers

    • Underwater speakers sit in a recessed metal forming shell with a bonded, tool-locked screen (NEC 680.27(A)(1)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.10.2

    Wiring Methods

    • Speaker conduit is brass RMC, PVC, RTRC or LFNC-B; nonmetallic conduit carries a potted 8 AWG bonding jumper (NEC 680.27(A)(2)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.10.3

    Forming Shell and Metal Screen

    • Speaker shells and screens are brass or corrosion-resistant metal with an 8 AWG termination (NEC 680.27(A)(3)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.14.1

    Unit Heaters

    • Unit heaters are rigidly mounted, enclosed or guarded, and not over the pool or within 5 ft of it (NEC 680.27(C)(1)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.14.2

    Permanently Wired Radiant Heaters

    • Radiant heaters are guarded, not over or within 5 ft of the pool, and at least 12 ft above the deck (NEC 680.27(C)(2)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

  • E4206.14.3

    Radiant Heating Cables Prohibited

    • Radiant heating cables in or under the pool deck aren't allowed (NEC 680.27(C)(3)).

    International Residential Code, 2024 · Chapter 42, Swimming PoolsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.