Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

11 sections matching “IBC 703.2” for San Antonio, TX, the 2024 IRC and IBC

  • IBC 703.2

    Fire resistance

    • Ratings come from tests or analysis (703.2.1, 703.2.2) without counting sprinklers, or an approved alternate (703.2.3).

    International Building Code, 2024 · Chapter 7, Fire and Smoke Protection FeaturesRead the full text (opens UpCodes in a new tab)

  • IBC 703.2.2

    Analytical methods

    • Ratings may come from approved-source designs, prescriptive 721 designs, 722 calculations, engineering comparison with tested assemblies, or agency-certified designs.

    Works withIBC 721IBC 722

    International Building Code, 2024 · Chapter 7, Fire and Smoke Protection FeaturesRead the full text (opens UpCodes in a new tab)

  • IBC 703.2.1.1

    Nonsymmetrical wall construction

    • Nonsymmetrical interior walls are tested from both sides and take the shorter result, unless the weaker side was shown tested.

    Works withIBC 705.5

    International Building Code, 2024 · Chapter 7, Fire and Smoke Protection FeaturesRead the full text (opens UpCodes in a new tab)

  • IBC 703.2.1.2

    Combustible components

    • Combustible aggregates and any admixtures are fine if the tested assembly passes.

    International Building Code, 2024 · Chapter 7, Fire and Smoke Protection FeaturesRead the full text (opens UpCodes in a new tab)

  • IBC 703.2.1.3

    Restrained classification

    • Assemblies count as restrained only with the design professional's evidence, shown on the drawings.

    International Building Code, 2024 · Chapter 7, Fire and Smoke Protection FeaturesRead the full text (opens UpCodes in a new tab)

  • IBC 703.2.1.5

    Exterior bearing walls

    • Exterior bearing walls meet temperature-rise and cotton-waste criteria only for the time a nonbearing wall at the same FSD would need.

    International Building Code, 2024 · Chapter 7, Fire and Smoke Protection FeaturesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes