Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

8 sections matching “IBC 407.2” for San Antonio, TX, the 2024 IRC and IBC

  • IBC 407.2

    Corridors continuity and separation

    • I-2 corridors run continuously to exits and are separated per 407.3, except spaces in 407.2.1 to 407.2.6.

    Works withIBC 407.3

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.1

    Waiting and similar areas

    • Waiting and meeting areas may open to corridors if not sleeping, treatment or hazardous, with detection and clear exit access.

    Works withIBC 907IBC 903.3.2

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.2

    Care providers' stations

    • Nurses' stations and charting areas may open to corridors.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.3

    Psychiatric treatment areas

    • Supervised psychiatric areas up to 1,500 sq ft may open to corridors, one per smoke compartment, with detection.

    Works withIBC 907.2

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.5

    Nursing home housing units

    • In I-2 Condition 1 nursing units, shared living spaces may open to corridors with detection or quick-response sprinklers.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.6

    Nursing home cooking facilities

    • Domestic kitchens may open to corridors serving 30 or fewer residents, one per smoke compartment.

    Works withIBC 407.2.7

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 407.2.7

    Domestic cooking appliances

    • Domestic cooking limited to ovens, cooktops, ranges, warmers and microwaves, with hood, cooktop suppression, staff shutoff, 120-minute timer and an extinguisher within 30 ft.

    Works withIBC 904.15IBC 906

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application