  • IBC 406.3

    Private garages and carports

    • Private garages and carports meet 406.2 and 406.3, or 406.2 and 406.4.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.3.1

    Classification

    • Private garages and carports are Group U, each up to 1,000 sq ft; multiple garages are separated by 1-hour construction.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.3.2

    Separation

    • Private garages next to dwelling units follow 406.3.2.1 and 406.3.2.2; others follow 508.

    Works withIBC 508

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.3.3

    Carports

    • Carports are open on at least two sides, or they count as garages.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.3.2.1

    Dwelling unit separation

    • Garage-to-dwelling separation: ½-in gypsum on the garage side; ⅝-in Type X under habitable rooms above; doors solid wood or steel 1⅜ in, or 20-minute rated, self-closing and self-latching.

    Works withIRC R302.6

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.3.3.1

    Carport separation

    • No separation is needed between R-3 and a carport open on two sides with nothing enclosed above.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 406.1

    General

    • Motor-vehicle occupancies meet 406.2, plus 406.3 (private), 406.4–406.6 (public garages), 406.7 (fuel) and 406.8 (repair).

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.