Every part of the home has a continuous path to the egress door that doesn't pass through the garage, and that door opens to a public way or a yard that reaches one.
Where data point to expansive, compressible or shifting soil, the building official decides whether a soil test is required; in SDC C and up the report gives site class and SDS.
On existing walls with no house wrap, add a barrier behind the ledger reaching 1/2 in past its sides and bottom, with a self-adhered counterflash lapping 2 in.
Exterior Insulation and Finish System (EIFS)/EIFS With Drainage
Barrier EIFS (ASTM E2568) goes only on concrete or masonry; elsewhere use drainable EIFS with 90% drainage and a WRB; both stop 6 in above grade with no trim nailed through.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.