  • R1003.12

    Clay Flue Lining (Installation)

    • Clay liners per ASTM C1283 run from 8 in below the lowest inlet (or the top of the smoke chamber) to above the walls, slope no more than 30 degrees, are laid in refractory mortar with smooth joints, and keep a gap no thicker than the liner.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R702.3.5.1

    Screw Fastening

    • Drywall screws are Type W or S into wood 5/8 in deep; into steel, No. 6 or larger, 3/8 in past light steel (Type S) or C954 screws for heavier steel; into SIPs 7/16 in.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

  • R802.4.1

    Rafter Size

    • Rafter sizes come from the span tables by species, grade, size, spacing, snow or live load and whether a ceiling is attached; spans are measured horizontally.
    • When ceiling joists or rafter ties sit higher in the attic, rafter spans shrink: to 67% at a third of the rise, 76% at a quarter, up to full span at 1/7.5 or lower.

    International Residential Code, 2024 · Chapter 8, Roof-Ceiling ConstructionRead the full text (opens UpCodes in a new tab)

  • R311.2.2

    Alterations, Repairs and Additions

    • Permitted interior work adds CO alarms to the unit, except for exterior work, plumbing, or non-fuel mechanical work.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.