Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 1,598 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R606.12.4

    Seismic Design Category D

    • In SDC D2, stack bond masonry gets horizontal steel of 0.15% at 24 in (non-bracing) or 0.25% at 16 in (bracing), solid grouted.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R405.1

    Concrete or Masonry Foundations

    • Basements and other below-grade living or usable spaces with concrete or masonry walls get a footing drain, unless the soil is Group I.
    • Gravel drains reach 1 ft past the footing and 6 in above it under filter fabric; pipe sits on 2 in of gravel and is covered by 6 in.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • R404.1.2.1

    Masonry Foundation Walls

    • Masonry foundation walls are sized from the plain or reinforced tables by wall height, backfill height and soil class; rubble stone isn't allowed in SDC D or for townhouses in C.
    • Unbalanced backfill is measured from outside grade down to the footing top or inside grade, or to the top of an interior slab bearing against the wall.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • R609.8

    Mullions

    • Mullions are tested to AAMA 450 or engineered, deflect no more than L/175, and hold 1.5 times design load with 0.4% or less permanent set.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application