Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 1,598 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R606.12.2

    Seismic Design Category C

    • Townhouse masonry in SDC C keeps 20-35% of each wall solid (segments 3 ft or more, gaps 18 ft or less), with No. 4 bars at corners, openings, ends and 10 ft, and connectors at 4 ft for 200 plf.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R1003.1

    Definition

    • A masonry chimney is built of solid or solid-grouted masonry, stone or concrete, and is built, anchored, supported and reinforced per this chapter.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R905.1.2

    Ice Barriers

    • Where ice dams are a known problem, run an ice barrier (two cemented layers or self-adhered) from the eave to 24 in inside the wall line, or 36 in up the slope on 8:12 and steeper roofs.

    Local review: San Antonio isn't normally an ice-dam area; check the city's Table R301.2 entry before adding an ice barrier requirement.

    International Residential Code, 2024 · Chapter 9, Roof AssembliesRead the full text (opens UpCodes in a new tab)

  • R302.9.5

    High-Density Polyethylene (HDPE) and Polypropylene (PP)

    • HDPE or polypropylene interior finish must pass the room-corner test.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application