Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 1,598 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R1003.17

    Masonry Chimney Cleanout Openings

    • Each flue has a cleanout within 6 in of its base, its top edge at least 6 in below the lowest inlet, at least 6 in tall, with a noncombustible cover; fireplace flues cleanable through the opening are exempt.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R1001.3.2

    Horizontal Reinforcing

    • Vertical bars are enclosed in 1/4-in ties (or equal area) in the bed joints at no more than 18 in vertically, with two ties at each bend.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R702.3.5

    Application

    • Drywall edges land on framing (except edges across it), and interior drywall never goes where weather or water hits it directly.
    • Without adhesive, drywall nails go 7 in apart on ceilings and 8 in on walls, screws 12 in (16 in on 16 in walls); framing is 16 in for 3/8 in board and up to 24 in for 1/2 and 5/8 in.
    • 5/8 in Type X on a garage ceiling under living space runs across 24 in framing with fasteners at 6 in.
    • With adhesive, fastener spacing opens to 12-16 in on ceilings and 16-24 in on walls; two-layer 3/8 in work nails the base ply and glues the face.
    • Ceilings getting water-based texture use 1/2 in board on 16 in framing or 5/8 in (or sag-resistant 1/2 in) on 24 in, laid across the joists; 3/8 in can't hold insulation or texture.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

  • R315.5.3

    Ladders

    • A loft ladder has rungs at least 12 in wide, 10 to 14 in apart and evenly spaced, holds 300 lb per rung, and leans 70 to 80 degrees.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.