Veneer on a steel angle uses at least a 6x4x5/16 in angle lagged to double studs at 16 in, with two-thirds of the brick bearing, up to 12 ft 8 in of veneer; slopes over 7:12 need stops.
Glass at tubs, showers, spas, saunas and pools is hazardous if its bottom is under 60 in above the standing surface, unless it's more than 60 in away from the water.
Where it meets a heated building, no insulation is needed between them, but it carries along the neighbour's foundation for Dimension A (not at inside corners).
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.