Chimneys up to 40 in wide get four continuous No. 4 vertical bars, grouted but kept from bonding to the flue liner; add two bars for each extra flue or each extra 40 in of width or part of it.
A habitable attic counts as a story unless it's no more than a third of the floor below (half if sprinklered), enclosed by the roof and knee walls, and within the walls below.
Construction joints in plain walls sit at lateral supports with No. 4 bars across them at 24 in or less, embedded 12 in each side; in reinforced walls, in the middle third of the span.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.