Masonry compressive stress stays within Table R606.9 values, using the weakest material in a mixed wall, and facing units carrying load are at least 1-1/2 in thick.
Ceiling joists run continuous or are joined over partitions, are nailed to the plates, and are sized from the ceiling joist span tables (10 psf no storage or 20 psf limited storage).
Footing rebar is Grade 40 or better, tied in place, with 3 in of cover against earth, 1-1/2 in (No. 5 and smaller) or 2 in in formed exposed concrete, and 3/4 in otherwise.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.