Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 1,598 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R703.6.3

    Attachment

    • Each shake or shingle takes two stainless or hot-dip galvanized nails (or stainless staples), hidden 1 in above the next butt and 3/4 in from the edge; within 15 miles of salt water, or on treated products, use 316 stainless.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

  • R602.10.3

    Required Length of Bracing

    • Required bracing length per line comes from the wind table (and the seismic table in SDC D or for SDC C townhouses), times the adjustment factors; only parallel panels count.
    • Wind bracing grows with exposure (C x1.2-1.4, D x1.5-1.7), taller roofs and walls and more wall lines; dropping interior gypsum adds 40%, and skipping horizontal blocking doubles it.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10.2.3

    Minimum Number of Braced Wall Panels

    • A braced wall line of 16 ft or less needs two panels or one panel of 48 in; longer lines need at least two panels.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R602.10

    Wall Bracing

    Used in checks
    • Houses are braced per R602.10 or the simplified method; any part that doesn't fit is engineered.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.