In Seismic Design Category D0 to D2, masonry or concrete chimneys are reinforced per Table R1001.1 and Section R606.
Local review: San Antonio sites are normally Seismic Design Category A or B, so chimney reinforcing and anchorage are usually not required; confirm the SDC for the site in Table R301.2.
Unrated floors get 1/2 in gypsum or 5/8 in wood panel under the framing, unless sprinklered below, over a plain crawl space, built of 2x10 or larger lumber, or a small detached accessory floor.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.