Flash at copings, wall-roof joints, slope or direction changes, openings and where an eave meets a sidewall (kick-out); metal flashing is at least 26-gauge (0.019 in).
Fireplace footings are concrete or solid masonry at least 12 in thick, extending 6 in past the fireplace or wall on every side, on undisturbed soil or engineered fill below frost depth.
A 1/2 in drywall ceiling can act as a diaphragm (90 plf at 16 in, 70 plf at 24 in) if laid across joists, no wider than 1.5:1, blocked at the edges with 2x6, and not used against masonry or concrete.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.