Rafters and ceiling joists bear 1-1/2 in on wood or metal and 3 in on masonry or concrete; on 3:12 or steeper roofs with a proper tie, bearing on the ridge board is enough.
With cold-formed steel framing, each bolt location gets a 3 x 3 x 0.229 in steel plate over the strap, screwed down with at least seven No. 6 screws per bolt.
In SDC D, exterior walls always sit on continuous concrete or grouted masonry footings; interior braced panels need them on larger or taller buildings.
Where interior bracing footings are needed, they may be spaced up to 50 ft apart if cripple walls are 4 ft or less, panels sit on doubled joists or beams, and bracing lines are no more than twice the building width apart.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.