Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 1,598 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R606.9

    Allowable Stresses

    • Masonry compressive stress stays within Table R606.9 values, using the weakest material in a mixed wall, and facing units carrying load are at least 1-1/2 in thick.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R802.4.1

    Rafter Size

    • Rafter sizes come from the span tables by species, grade, size, spacing, snow or live load and whether a ceiling is attached; spans are measured horizontally.
    • When ceiling joists or rafter ties sit higher in the attic, rafter spans shrink: to 67% at a third of the rise, 76% at a quarter, up to full span at 1/7.5 or lower.

    International Residential Code, 2024 · Chapter 8, Roof-Ceiling ConstructionRead the full text (opens UpCodes in a new tab)

  • R905.10

    Metal Roof Panels

    • Metal panels go on solid or spaced decks; lapped seams need 3:12 (1/2:12 with sealant) and standing seams 1/4:12; materials and coatings meet the metal tables, with matching fasteners.

    International Residential Code, 2024 · Chapter 9, Roof AssembliesRead the full text (opens UpCodes in a new tab)

  • R315.5.3

    Ladders

    • A loft ladder has rungs at least 12 in wide, 10 to 14 in apart and evenly spaced, holds 300 lb per rung, and leans 70 to 80 degrees.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application