In windborne debris regions, exterior glazing needs large-missile impact protection; garage door glazing uses an approved impact standard or ANSI/DASMA 115.
Precut wood structural panels can serve as opening protection if they are at least 7/16 in thick and span 8 ft or less, with anchors installed permanently.
Max anchor spacing for debris-protection panels depends on anchor type and panel span; anchors embed at least 2 in.
Exterior concrete walls follow this section, PCA 100, ACI 318 or ACI 332, with light-frame interiors; drawings needn't be sealed unless state law says so.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.