  • R306.2.1

    Elevation Requirements

    • In A Zones the lowest floor, basement included, is at least 1 ft above base flood or at the design flood level, whichever is higher.
    • In AO shallow-flood zones, the lowest floor is the mapped depth plus 1 ft above the highest adjacent grade, or 3 ft if no depth is mapped.
    • A detached garage or shed may sit below flood level if it's one story, 600 sq ft or less, storage or parking only, anchored, vented and flood-resistant.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R606.3.6

    Grouted Multiple-Wythe Masonry

    • Fully grouted multi-wythe walls use metal ties instead of headers, with grout dams no more than 25 ft apart, each section grouted in one day.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

  • R318.3

    Floors and Landings at Exterior Doors

    • Every exterior door has a landing on each side as wide as the door and at least 36 in deep, sloping no more than 2%.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R502.3.3

    Floor Cantilevers

    • A floor cantilever reaches no farther than the joist depth, unless it follows the tables for a bearing wall and roof or a balcony.
    • Cantilevers get a full-depth rim at the end and solid blocking at the support; blocking can be skipped for cantilevers of 24 in or less in SDC A to C.
    • Table cantilevers need a backspan of at least 3 times the cantilever under a wall and roof, or 2 times for a balcony, with uplift ties at the backspan.

    International Residential Code, 2024 · Chapter 5, FloorsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.