  • R507.6.2

    Deck Joist Lateral Restraint

    • Deck joists are held against rolling; hangers or blocking are at least 60% of joist depth, and rim joists take three 10d nails or No. 10 screws per joist.

    International Residential Code, 2024 · Chapter 5, FloorsRead the full text (opens UpCodes in a new tab)

  • R803.2

    Wood Structural Panel Sheathing

    • Roof panels are graded and marked, exterior-rated if permanently exposed (Exposure 1 is fine underneath), span per the panel table, and overhang gable ends no more than 9 in without framing.

    International Residential Code, 2024 · Chapter 8, Roof-Ceiling ConstructionRead the full text (opens UpCodes in a new tab)

  • R302.13

    Fire Protection of Floors

    • Unrated floors get 1/2 in gypsum or 5/8 in wood panel under the framing, unless sprinklered below, over a plain crawl space, built of 2x10 or larger lumber, or a small detached accessory floor.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R404.1.4.1

    Masonry Foundation Walls

    • In SDC D, plain masonry foundation walls are at most 8 ft tall with 4 ft of backfill, at least 8 in thick, with No. 4 verticals at 4 ft and two No. 4s in the top 12 in.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.