  • R1005.3

    Solid-Fuel Appliances

    • In dwellings, factory-built chimneys for solid-fuel appliances meet UL 103 Type HT and carry its markings; chimneys for open fireplaces need UL 103 without the HT rating.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R403.1.2

    Continuous Footing in Seismic Design Categories D

    • In SDC D, exterior walls always sit on continuous concrete or grouted masonry footings; interior braced panels need them on larger or taller buildings.
    • Where interior bracing footings are needed, they may be spaced up to 50 ft apart if cripple walls are 4 ft or less, panels sit on doubled joists or beams, and bracing lines are no more than twice the building width apart.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • R602.7.4

    Nonbearing Walls

    • Nonbearing walls need no structural header; a flat 2x4 works up to 8 ft if the nailing surface above is within 24 in.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.