Rafters meet opposite each other at the ridge (no more than 1-1/2 in offset), tied with a collar tie, ridge strap or gusset, and nailed to the plates unless uplift connectors are required.
Exterior Soffit Installation Where the Design Wind Pressure Exceeds 30 psf
Over 30 psf, soffits are rated for the wind; vinyl needs intermediate support over 12 in, and plywood soffit can follow the prescriptive nailing table up to 90 psf.
Location of Braced Wall Lines and Permitted Offsets
Braced wall lines are straight lines in plan; panels, exterior walls and interior bracing walls may sit up to 4 ft off the line, with no more than two-thirds of the bracing on one side.
Roofs that don't drain off their edges need a drain at every low point, plus overflow drains (2 in above the low point) or scuppers three times the drain size and 4 in tall where parapets could trap water.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.