Cripple walls are braced like the wall above, with 15% more length; in SDC D0/D1 and SDC C townhouses only panel methods, with panels no more than 14 ft apart.
Cripple walls 48 in or shorter can count as the first story; if any part is taller, the cripple wall is an extra story.
Exterior Soffit Installation Where the Design Wind Pressure Is 30 psf or Less
Up to 30 psf: vinyl or aluminum soffit fastened both ends with intermediate strips over 16 in; fiber-cement 1/4 in; hardboard 7/16 in and plywood 3/8 in nailed 6 in edge, 12 in field.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.