  • R703.8.2.1

    Support by Steel Angle

    • Veneer on a steel angle uses at least a 6x4x5/16 in angle lagged to double studs at 16 in, with two-thirds of the brick bearing, up to 12 ft 8 in of veneer; slopes over 7:12 need stops.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

  • R1003.4.1

    Anchorage

    • Two 3/16 x 1 in straps embed 12 in into the chimney, hook the outer bars with a 6 in tail, and each fasten to at least four joists with two 1/2-in bolts.

    International Residential Code, 2024 · Chapter 10, Chimneys and FireplacesRead the full text (opens UpCodes in a new tab)

  • R703.6.3

    Attachment

    • Each shake or shingle takes two stainless or hot-dip galvanized nails (or stainless staples), hidden 1 in above the next butt and 3/4 in from the edge; within 15 miles of salt water, or on treated products, use 316 stainless.

    International Residential Code, 2024 · Chapter 7, Wall CoveringRead the full text (opens UpCodes in a new tab)

  • R804.3.1

    Ceiling Joists

    • Steel ceiling joists are sized from the span tables by bracing, bear 1-1/2 in, are screwed to rafters per the heel table, and continuous joists need supports within 24 in of midspan; occupied attics follow the floor rules.
    • Steel ceiling joist bottoms are braced by gypsum or 1-1/2 in straps at 4 ft; tops by 33-mil members or straps per the tables, with blocking every 12 ft; splices only over bearings.

    International Residential Code, 2024 · Chapter 8, Roof-Ceiling ConstructionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.