Skip to content

Search the building code.

Every 2024 IRC section and the IBC as it loads, by number or topic, plus the local rules for your city. Free to search.

Detached houses, duplexes and townhouses up to 3 stories with their own exits use the IRC; every other building uses the IBC (IBC 101.2).

A random sample from 1,598 sections for San Antonio, TX, the 2024 IRC

Show another sample
  • R302.4.1

    Through Penetrations

    • Through penetrations of rated separations are protected as tested, or with a listed firestop whose F rating at least equals the wall's rating.
    • Metal pipes through concrete or masonry may be grouted if the pipe is 6 in or smaller and the hole is no more than 144 sq in.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R318.7.13

    Ship's Ladders

    • Ship's ladders can't be egress, except for small lofts and mezzanines; they're at least 20 in wide with handrails on both sides.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R408.3

    Unvented Crawl Space

    • Unvented crawl spaces cover the ground with sealed Class I vapor retarder (6 in laps, 6 in up the walls) and get exhaust, conditioned air at 1 cfm per 50 sq ft, plenum use or a dehumidifier.

    International Residential Code, 2024 · Chapter 4, FoundationsRead the full text (opens UpCodes in a new tab)

  • R602.10.8.2

    Connections to Roof Framing

    • Braced panels tie to the roof: in SDC A-C no blocking up to 9-1/4 in of heel, blocking up to 15-1/4 in, and blocking panels beyond; in SDC D blocking from the start.

    International Residential Code, 2024 · Chapter 6, Wall ConstructionRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application