Parallel braced wall lines are no more than 60 ft apart for wind; seismic limits are 35 ft for SDC C townhouses and 25 ft in SDC D, with allowed stretches to 35 or 50 ft.
Concrete is consolidated around bars and into corners; stay-in-place forms are vibrated internally unless self-consolidating mix of 8 in slump or more is approved.
Deck guards meet R301.5 and R321 and carry their loads continuously into the joists; side-mounted guards brace the rim against rolling, with no end-grain-only fasteners.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.
Check your plans against these codes
Start an application and get every flag with its section and fix.