In A Zones the lowest floor, basement included, is at least 1 ft above base flood or at the design flood level, whichever is higher.
In AO shallow-flood zones, the lowest floor is the mapped depth plus 1 ft above the highest adjacent grade, or 3 ft if no depth is mapped.
A detached garage or shed may sit below flood level if it's one story, 600 sq ft or less, storage or parking only, anchored, vented and flood-resistant.
Brick and stone veneer on wood or steel framing is 5 in or thinner and one story, except in SDC A-C up to 30 ft (plus 8 ft of gable) at 50 psf or less.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.