30 sections matching “R302.1” for San Antonio, TX, the 2024 IRC

  • R302.1

    Exterior Walls

    Used in checks
    • An unsprinklered house's exterior walls closer than 5 ft to the lot line need a 1-hour rating, tested from both sides.
    • Unsprinklered: no projections within 2 ft of the line; 1-hour underside from 2 to under 5 ft; unrated at 5 ft or more.
    • Unsprinklered: no wall openings within 3 ft; up to 25% of the wall at 3 ft to under 5 ft; unlimited at 5 ft or more.
    • Penetrations within 3 ft of the lot line are protected per R302.4.
    • A fully sprinklered house only needs rated walls (tested from outside) under 3 ft; openings are unlimited from 3 ft and projections can be rated from 2 ft.
    • In a fully sprinklered subdivision, the separation distance can drop to 0 ft where the neighbouring lot keeps an open yard of 6 ft or more.
    • Two homes on one lot measure to an imaginary line between them; townhouses measure to the lot line or an imaginary line.
    • Exempt: walls perpendicular to the line, the owner's own accessory buildings, permit-exempt sheds, and foundation vents. A detached garage within 2 ft of the line may have eaves of up to 4 in.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.11

    Fireblocking

    • Wood framing gets fireblocking at every floor and ceiling line, every 10 ft horizontally, at soffits and drop ceilings, at stair stringer ends and around penetrations.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.12

    Draftstopping

    • With usable space above and below, draftstops keep concealed floor-ceiling spaces at 1,000 sq ft or less where the ceiling is suspended or the floor uses open-web trusses.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.13

    Fire Protection of Floors

    • Unrated floors get 1/2 in gypsum or 5/8 in wood panel under the framing, unless sprinklered below, over a plain crawl space, built of 2x10 or larger lumber, or a small detached accessory floor.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.14

    Combustible Insulation Clearance

    • Keep combustible insulation at least 3 in from recessed lights, fan motors and other heat sources unless the listing allows less.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.15

    Fire-Retardant-Treated Wood

    • Fire-retardant-treated wood has a flame spread index of 25 or less, and in an extended 20-minute test the flame front stays within 10.5 ft.
    • Each FRTW piece is labelled, and is dried to 19% moisture or less for lumber and 15% or less for panels; interior FRTW stays at or below 28% at 92% humidity.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.10.1

    Insulation

    • Insulation, facings included, has a flame spread index of 25 or less and a smoke index of 450 or less.
    • Non-sprayed cellulose loose fill only needs the 450 smoke limit, tested to CAN/ULC S102.2.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.10.3

    Cellulosic Fiber Loose-Fill Insulation

    • Cellulose loose fill meets and is labelled to the CPSC rules in 16 CFR 1209 and 1404.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.10.4

    Exposed Attic Insulation

    • Exposed insulation on an attic floor needs a critical radiant flux of at least 0.12 W/cm2.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.11.1

    Fireblocking Materials

    • Accepted fireblocks include 2 in lumber, doubled 1 in lumber, 23/32 in panels, 3/4 in particleboard, 1/2 in gypsum, 1/4 in cement millboard, secured batts or tested cellulose.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

  • R302.11.1.2

    Unfaced Fiberglass

    • Unfaced fiberglass used as fireblocking fills the whole cavity at least 16 in high, packed around pipes.

    International Residential Code, 2024 · Chapter 3, Building PlanningRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.