7 sections matching “IBC 415.8” for San Antonio, TX, the 2024 IRC

  • IBC 415.8

    Special provisions for Group H-2 and H-3 occupancies

    • H-2/H-3 above Table 415.6.5 quantities go in detached buildings.

    Works withIBC 307.3

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 415.8.1

    Multiple hazards

    • Materials that are both physical and health hazards meet H-2, H-3 or H-4 as applicable.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 415.8.2

    Separation of incompatible materials

    • Incompatible materials are separated per the IFC.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 415.8.3

    Water reactives

    • Water-reactive areas resist water; liquid piping doesn't run over them except sprinklers.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 415.8.4

    Floors in storage rooms

    • Floors storing reactives, oxidizers and peroxides are liquid-tight and noncombustible.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 415.8.5

    Waterproof room

    • Water-reactive storage rooms are waterproof with only sprinkler piping inside.

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

  • IBC 415.6.5

    Detached buildings for Group H-1, H-2 or H-3 occupancy

    • Quantities above Table 415.6.5 (e.g. Class 3 oxidizer 1,200 tons, Class 2 2,000 tons) require detached buildings per 415.7 and 415.8.

    Works withIBC 415.7IBC 415.8

    International Building Code, 2024 · Chapter 4, Special Detailed Requirements Based on Occupancy and UseRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.