2 sections matching “IBC 803.1.1.1” for San Antonio, TX, the 2024 IBC

  • IBC 803.1.1.1

    Acceptance criteria for NFPA 286

    • No flame to the ceiling at 40 kW, no spread to sample edges, no flashover, peak heat release 800 kW or less, total smoke 1,000 m² or less.

    International Building Code, 2024 · Chapter 8, Interior FinishesRead the full text (opens UpCodes in a new tab)

  • IBC 803.1.1

    Interior wall and ceiling finish materials tested in accordance with NFPA 286

    • Finishes passing NFPA 286 per 803.1.1.1 count as Class A.

    International Building Code, 2024 · Chapter 8, Interior FinishesRead the full text (opens UpCodes in a new tab)

Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.

Check your plans against these codes

Start an application and get every flag with its section and fix.

Start an application