IBC 107.1
General
Construction documents, the statement of special inspections, the geotechnical report and other data are submitted (two sets or digital), prepared by a registered design professional where state law requires.
A scaled site plan from a boundary survey shows new and existing structures, distances from lot lines, street and finished grades, and any flood areas and design flood elevations.
Where sealed documents are required, the owner names a registered design professional in responsible charge who coordinates all submittals, and reports any change in writing.
Deferred submittals need the official's prior approval, are listed on the documents, reviewed by the design professional in charge, and not installed until approved.
Searches all 4,276 IRC 2024 sections, 5,532 IBC 2024 sections and defined terms (Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33 so far) and each city's local rules as they are added. Section numbers and titles from the International Residential Code and International Building Code, 2024 editions, copyrighted by the International Code Council; the IRC's electrical chapters (34 to 43) follow NFPA 70, the National Electrical Code. Requirements are summarized in our words (IRC Chapters 3 to 43, IBC Chapters 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33); read the full text at the link on each result. Local values come from each city's published documents.